A Site Acceptance Test (SAT) is the qualification phase followed by the Extra fat and it includes a number of testing finished on devices, performed for the operator representative site.
A failure to proper a fault in the pre-agreed time-frame is usually enough justification for that finish consumer to terminate the agreement.
Economical documentation and handover procedures are important for concluding the SAT process and transferring the PLC method for the customer. Listed here’s a concise define:
This guideline presents an extensive overview in the SAT process personalized specifically for PLC units, making certain complete testing and verification of operation at consumer sites.
Delays in obtaining the necessary gear or utilities for that tests could potentially cause considerable setbacks inside the testing schedule.
Testing verifies personal parts from precise standards, when commissioning makes certain that all devices operate jointly effectively to satisfy the overall project objectives.
Established because of the GDPR Cookie Consent plugin, this cookie is utilized to file the person consent for your cookies while in the "Advertisement" classification .
In the Site Acceptance Test (SAT) for PLC techniques, complete testing of input/output (I/O) loops is very important to be sure appropriate performance and integration with peripheral devices. This section outlines The crucial element techniques involved in conducting I/O loop testing:
Among the reasons of an SAT, after A prosperous FAT, is to provide documented proof that a bit of apparatus or procedure which has been sent get more info to the tip-user site hasn't been influenced with the transportation or set up.
Inspect electrical field wiring to validate its integrity, suitable termination, and compliance with safety criteria. Any deviations or problems should be addressed before proceeding Using the SAT.
Acquire official acceptance through the client the PLC method satisfies their requirements and is prepared for operational more info use.
Verify the performance of analog inputs and outputs (AI/AO) by applying test signals within the specified vary and observing the PLC’s response.
Inside the absence of practical testing, the proprietor will very likely be unaware of The mixing difficulty and won't recoup the financial savings from occupancy-primarily based demand from customers Command ventilation.
A further aim is assessing the creating’s operational readiness. This entails examining Electrical power devices and verifying assist for intended capabilities, for instance ample lighting for efficiency or exact climate Regulate in sensitive spots.